Part Number: LMK03806BEVAL Other Parts Discussed in Thread: LMK04806 , LMK03806 Tool/software: Hi,
Customer is evaluating EVM for from 12MHz~25MHz output clock.
In the TICS pro, it shows 25MHz and 12MHz but they are actually 5.2% higher than calculation…
Part Number: DAC37J82 Other Parts Discussed in Thread: DAC37J84 , LMK04806 , Hello,
My customer wants to use the DAC37J84 under the following conditions.
- DACCLK P/N (Input CLK) = 1258.2912Mhz (From LMK04806) - DACCLK (PLL out) = 943.7184Mhz (DAC…
Part Number: LMK03806 Other Parts Discussed in Thread: LMK04806 Hellow
I designed LMK03806 board.
and using TICS Pro generate register.
problem does not locked clock.
schematic is below
input frequency : 30.72MHz TCXO and Vp-p is 3.3V
…
Other Parts Discussed in Thread: LMK04806 I am trying to configure this PLL: LMK04806BISQE/NOPB to generate the following clocks:
CLKout0: 266.24MHz (2396.16/9)
CLKout1: 266.24MHz (2396.16/9)
CLKout2: 798.72MHz (2396.16/3)
CLKout3: 798.72MHz …
Part Number: LMK03806 Other Parts Discussed in Thread: LMK04806 Hello,
My customer wnats to use the sync pin of the LMK03806 to synchronize the phase of all the clock outputs.
For this, please explain in detail how to control the sync pin.
When…
Part Number: ADS54J42 Other Parts Discussed in Thread: LMK04806 Hello,
My customer has an issue of the ADS54J42 SNR performance degradation with thier custom board under the following conditions.
- RF input = 368.64MHz, Bandwidth = 200MHz
- CLKIN…
Hi Timothy,
I am considering to replace the LMK03806 on board with LMK04806, but I am wondering the software compatibility from LMK03806 to LMK0486. It seems their register arrangement(R0~R31) is pretty the same. Do you know whether I can still use…
Santiago,
Also consider using the PLLatinum Sim tool (ti.com/tool/PLLATINIMSIM-SW) that can be used to simulate and design the LMK04806 loop filter.
Regards,
Dean
Part Number: TMS320F280049 Other Parts Discussed in Thread: TMS320F28386S , LMK04806 Hi everyone,
I have been using the TMS320F280049 for awhile in active battery balancing systems. CAN communication (batteries mostly use CAN communication) in TMS320F280049…
Hello, and thank you. I use WIndows 10 64 bit. What is CDT? My part of iterest is LMK04828 and as I used the Clock Design SW for my previous use of LMK04806 I considered i would need the same SW in this case. They are not part of Platinum family as far…