Part Number: TLV2374 Other Parts Discussed in Thread: TLV2373 Hello,
TLV2374 has 4 opamps, currently our application uses 3, should be left the 4th opamp connections floating or, should I simply tie to GND ?
There is a possibility that we can use…
Other Parts Discussed in Thread: TLV2373 , TLV2372 I am using TLV2373 as an amplifier in single supply mode. since the input signal to the amplifier contains both dc and ac voltages. so in order to decouple dc from the amplified signal i am using a decoupling…
Hi Arvind Raj,
Thanks for replying. :)
The op amps i used are TLV2463 and OPA2373.
Previously i used TLV2373 (lower GBW), same problems on gain happened (theoritical gain not same as measured gain, the gain was set to 75 when using TLV2373, but…
The OPA145 also looks like a good choice, this file has not been recently updated so the OPA196 is not in yet, and the pricing is out of date.
OPA111A options.xlsx
to User473,