Part Number: HDC2010 Tool/software: HI TI
My device uses HDC2010, but condensation always occurs on the device during use. Due to condensation, the pins of HDC2010 are short circuited.
May I ask how to waterproof HDC2010?
Can I apply conformal coating…
Part Number: HDC2010 Tool/software: At present, the design of our product mechanism is as shown in the diagram on the TI document, but there is a 1cm gap between the IC and the mechanism hole on our PCB. However, I refer to the TI design document and…
Part Number: HDC2010 Tool/software: Hi teams,
Customer has questions regarding to the product HDC2010.
Just want to clarify if the turning on test process is correct: Sensor at sleep mode(default) >> Trigger on Demand mode >> Turn OFF the system but keep…
Part Number: HDC2010 Tool/software: Hi,
Could you please provide cross-section figure of HDC2010 for my customer Lumi?
Thank you.
(like this)
BR,
Yishan Chen
Part Number: HDC2010 Tool/software: Hi expert,
Customer used HDC2010 with multiple windows (openings not aligned). May we learn from your experience is there any more guidelines or like gaps of height between the chip sensing area to the window can share…
Part Number: HDC2010 Tool/software: Hey team,
Can you please assist with the following questions?
The spec calls out a minimum I2C frequency of 10 kHz. Is this real or just boilerplate? In one usage of this sensor we run it with a software bit-bang…
Part Number: HDC2010 Other Parts Discussed in Thread: LP-MSPM0L1306 , , MSPM0L1306 , SYSCONFIG Tool/software: Hello Support-Team,
I assembled the HDC2010 on my product launchpad LP-MSPM0L1306 and now i am trying to get it worked. So, I am not using the EVM…
Part Number: HDC2010 Tool/software: Hi expert,
May I know what's the RH Response Time defined in the HDC2010 DS e.g. what's the temperature, and rate of airflow...etc?
Thanks,
Allan
Part Number: HDC2010 Tool/software: Hi team,
do we have recommendation for below request? better to be latest roadmap product with better cost.
Working voltage: 3V Working temperature and humidity range: -40~125℃, 0-100%RH Temperature and humidity test…
Part Number: HDC2010 Tool/software: Hi TI Engineer,
One of our customers have reported that the humidity measured by the HDC2010 is too high, they compared the data under the same environment, including actual working conditions and office conditions…