This thread has been locked.
If you have a related question, please click the "Ask a related question" button in the top right corner. The newly created question will be automatically linked to this question.
TI Team,
We are using the MSP-EXP430F5529LP as HID Bridge for Energy Monitoring DC as described in the following link.
http://software-dl.ti.com/msp430/msp430_public_sw/mcu/msp430/EnergyMeasurementDesignCenter/1_30_00_00/release/EnergyMeasurementDesignCenter_1_30_00_00/docs/users_guide/html/Energy_Measurement_Technology_Guide_html/markdown/ch_designcenter.html#
Regards,
Walter
Hello Walter,
If the EMDC GUI is displaying this message, then I suspect you didn't program the F5529 LaunchPad with the provided HID bridge image. Have you been following the instructions in the Out-of-Box Experience section of the Technology Guide? It will guide you step-by-step through this process.
Regards,
James
We put the connection, after programming HID but cannot read results. The display is like this, even AC is powered.
Do we need to program the EVM430-i2040S EVM with EVM430-i2040S_SH_1V_1C_60Hz also?
Regards,
W alter
Walter Macamos said:We put the connection, after programming HID but cannot read results. The display is like this, even AC is powered.
Looking at your other thread, the jumpers seem to be correct on the EVM430-i2040S for using its on-board power supply. Make sure all the connections are correct and contacting.
Walter Macamos said:Do we need to program the EVM430-i2040S EVM with EVM430-i2040S_SH_1V_1C_60Hz also?
Yes. As I pointed out earlier, these instructions are found in the Out-of-Box Experience section of the Technology Guide (specifically the Program the EVM section). Following these directions will help you overcome these types of issues and speed up your evaluation.
Regards,
James
**Attention** This is a public forum