This thread has been locked.
If you have a related question, please click the "Ask a related question" button in the top right corner. The newly created question will be automatically linked to this question.
For REFCLKP/N clock rate the possible suggested is either 50MHz or 62.5MHz or 125MHz, and the corresponding Line Rate is 625Mbps or 1250Mbps.
TMS320DM647/DM648 DSP 3 Port Switch Ethernet Subsystem User's Guide (Rev. B)
http://www.ti.com/lit/ug/spruf57b/spruf57b.pdf
1.4 Clocks (Page 19)
Does the 50 ps pk-pk apply regardless of which reference clock rate is used?
If not, what is the jitter requirement for each reference clock rate?
Does the 50 ps pk-pk apply to the 625Mbps line rate?
If not, what is the jitter requirement for the 625Mbps line rate?
Best regards,
Daisuke
Daisuke,
We need to check with the IP designer to see if the 50ps pk-pk can be relaxed for the 625Mbps mode.
Daisuke,
I'm waiting on the reply from the IP designer. Will let you know soon his reply.
Daisuke,
It would take a long amount of time to validate a lower jitter requirement for the slower data rate. At this point in time, we must use the same spec for both data rates.