This thread has been locked.
If you have a related question, please click the "Ask a related question" button in the top right corner. The newly created question will be automatically linked to this question.
Hello Higa,
I see that this data (output voltage vs. output current plot) is missing from the TVL316 datasheet on page 14:
We'll try and dig up that information and if possible add to the datasheet.
In the meantime, you may be able to use the modeled output characteristics from this other E2E post:
Regards,
Hooman
Hello Higa,
The TLV316 is closely affiliated with the OPA316 with fewer guaranteed limits.
Since the typicals are the same, the graphs for the OPA316 should still be valid. The OPA316 datasheet has the output “claw curve” on page 12 shown below:
We will try and update the TLV316 datasheet to reflect this.
Regards,
Hooman