TI E2E support forums
TI E2E support forums
  • User
  • Site
  • Search
  • User
  • E2E™ design support >
  • Forums
    • Amplifiers
    • API solutions
    • Audio
    • Clock & timing
    • Data converters
    • DLP® products
    • Interface
    • Isolation
    • Logic
    • Microcontrollers
    • Motor drivers
    • Power management
    • Processors
    • RF & microwave
    • Sensors
    • Site support
    • Switches & multiplexers
    • Tools
    • Wireless connectivity
    • Archived forums
    • Archived groups
  • Technical articles
  • TI training
    • Tech days
    • Online training
    • Live events
    • Power Supply Design Seminar
  • Getting started
  • 简体中文
  • More
  • Cancel
Logic

Logic

Logic forum

  • Mentions
  • Tags
  • More
  • Cancel
  • Ask a new question
  • Ask a new question
  • Cancel
Texas Instruments (TI) Logic support forum is an extensive online knowledge base where millions of technical questions and solutions are available 24/7. You can search logic IC content or ask technical support questions on everything from voltage level translation and transceivers to standard logic gates and specialty logic devices. Find the right solution for your circuit design challenges by using our TI E2E™ support forums that are supported by thousands of contributing TI experts.
Frequent questions
  • [FAQ] The thermal information in the datasheet has changed! What does this mean for me?

    Nikki Dengel
    Nikki Dengel
    FAQ: Logic and Voltage Translation > Power and Thermals >> Current FAQ We have been updating the thermal values in our datasheet, so you may have received a notification about datasheet changes to the thermal values or noticed a datasheet revision about…
    • Answered
    • 8 months ago
    • Logic
    • Logic forum
  • [FAQ] Can TXG support IEC-ESD for offboard connections

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ TXG devices (both push-pull and open-drain) cannot support any level of IEC-ESD. However, IEC-ESD can still be achieved by using a protection device like the ESDS30x product…
    • 10 months ago
    • Logic
    • Logic forum
  • [FAQ] How far apart can two systems be when using ground-level translator devices?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG8122-Q1 Open-Drain Architecture For I2C applications, the allowable distance between systems is primarily limited by total bus capacitance. The I2C specification limits bus capacitance to 400pF for Standard and…
    • 10 months ago
    • Logic
    • Logic forum
  • [FAQ] Will TXG QFN packages support wettable flank?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ At the moment TXG QFN packages do not support wettable flanks. However, we are working towards supporting wettable flank packages once products are fully released. The QFN…
    • 10 months ago
    • Logic
    • Logic forum
  • [FAQ] What is the leakage between two grounds?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG1041 FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The leakage between two grounds is specified in the Electrical Characteristics section in the device datasheet. The table below shows…
    • 10 months ago
    • Logic
    • Logic forum
  • [FAQ] Can TXG be used as a simple level translator / buffer?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The TXG product family can be used as a standard level translator (VCCA > VCCB or VCCA < VCCB) or in a buffer configuration when VCCA equals VCCB. If ground shifting is not…
    • 10 months ago
    • Logic
    • Logic forum
  • [FAQ] What is the maximum trace length ground-level translators can drive?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The maximum trace length that ground-level translators (as well as logic devices) can drive is 60 mm. This is a safe trace length for most devices to drive across the majority…
    • over 1 year ago
    • Logic
    • Logic forum
  • [FAQ] Is DC ground shifting possible when both supplies are connected together?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ Ground shifting requires the voltage supplies to be separated and to remain within the recommended operating conditions. In the image below, GNDB shifts by -5V due to parasitic…
    • over 1 year ago
    • Logic
    • Logic forum
  • [FAQ] Can a negative PWM signal be generated from a positive PWM signal?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG8041 FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ A negative PWM signal can be generated using a ground-level translator if the system includes a negative supply rail. To prevent…
    • over 1 year ago
    • Logic
    • Logic forum
  • [FAQ] Ground-Level Translators

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > > Current FAQ [FAQ] What are the differences between Ground-Level Translators and Digital Isolators? [FAQ] Can I generate a negative PWM signal from a positive PWM signal? [FAQ] Is DC ground shifting possible…
    • over 1 year ago
    • Logic
    • Logic forum
>

View FAQ threads
  • Tags
  • RSS
  • More
  • Cancel
  • Not Answered

    [FAQ] Frequently Asked Questions: TPLD 0 Locked

    3063 views
    0 replies
    Started over 1 year ago
    by Malcolm Lyn
  • Answered

    [FAQ] [H] Frequently Asked Questions: Logic and Voltage Translation 0 Locked

    46919 views
    1 reply
    Latest over 4 years ago
    by Michael J Schultis
  • Answered

    TXS0104W: TXS0104WRUT unused pins 0

    50 views
    2 replies
    Latest 1 hour ago
    by Brani Dubocanin
  • Not Answered

    SN74LVT16245B: Information Request 0

    62 views
    5 replies
    Latest 5 hours ago
    by Kollin Ewing
  • Suggested Answer

    SN74HC157A: input undershoot of the SN74HC157A 0

    35 views
    2 replies
    Latest 7 hours ago
    by Kollin Ewing
  • Not Answered

    TPSM82864A: Cross Reference Request for MPS Power Modules (MPM54504, MPM82504) due to Lead Time Issue 0

    25 views
    1 reply
    Latest 7 hours ago
    by fudong chen
  • Suggested Answer

    SN74LV244A: Clarification Needed: SN74LV244ARGYR Bond Wire Style/Item No. in SGS Report 0

    24 views
    1 reply
    Latest 7 hours ago
    by Nikki Dengel
  • Suggested Answer

    TXS0108E: TXS Level Translator used for DDC lines of HDMI causing issue 0

    170 views
    11 replies
    Latest 8 hours ago
    by Tyler Townsend
  • Suggested Answer

    TMUX4053: TMUX4053PWR burns out 0

    83 views
    7 replies
    Latest 8 hours ago
    by Clemens Ladisch
  • Not Answered

    LSF0108: Facing issue with signal rise time 0

    28 views
    2 replies
    Latest 8 hours ago
    by Tyler Townsend
  • Suggested Answer

    SN74HCS244: Verification of VIH and VIL thresholds and minimum pulse width requirements for Schmitt-trigger inputs 0

    12 views
    1 reply
    Latest 8 hours ago
    by Clemens Ladisch
  • Suggested Answer

    SN74LVC2G17: Buffer output behaviour 0

    22 views
    1 reply
    Latest 8 hours ago
    by Clemens Ladisch
  • Suggested Answer

    SN74LVC2G17: Need confirmation on both MPNs SN74LVC2G17DBVRG4 & SN74LVC2G17DBVRG4.B 0

    20 views
    1 reply
    Latest 8 hours ago
    by Clemens Ladisch
  • Not Answered

    SN74AUP1G07: FMA SN74AUP1G07DBVR 0

    10 views
    0 replies
    Started 13 hours ago
    by pouyadou luc
  • Suggested Answer

    SN74LVTH244A: Max Tj 0

    24 views
    2 replies
    Latest 1 day ago
    by Kollin Ewing
  • Suggested Answer

    SN74ACT14: SN74ACT14 Inverter circuit failure 0

    245 views
    16 replies
    Latest 2 days ago
    by Matthew Komitsky
  • Suggested Answer

    SN74AVC2T45: Received DT2 61 Z in place of DT2 58Z 0

    135 views
    8 replies
    Latest 2 days ago
    by Joshua Salinas
  • Suggested Answer

    SN74LVC1G17-Q1: NA 0

    38 views
    1 reply
    Latest 2 days ago
    by Kollin Ewing
  • Suggested Answer

    INTERCONNECT-STUDIO: Regarding an Interconnect Studio Simulation Issue 0

    89 views
    6 replies
    Latest 2 days ago
    by Kollin Ewing
  • Suggested Answer

    SN54ABT16244: Change of PN? 0

    31 views
    2 replies
    Latest 2 days ago
    by Kollin Ewing
>