Hi Bob,
You mean without NCO on like this:
However, here are some updates:
1) I tried to import capture data, of the signal 400MHz(-5dBm), JMODE16,Fs=3200MSPS, NCO is 400MHz, GAIN BOOST is on and set device parameteres like:
and the complex…
The issue with black stripes is not the highest priority now, it can be resolved last.
I wrote about the bt.656 mode earlier.
Butko Oleg43 said:
B4. tvp5150 detected by the system: ( Log v4l2-ctl - all -d / dev / video1 -V )
out_v4l2-ctl.log …
Dear Jim,
Thanks for your kind reply,
It means that I should use one IBUFDS each for every data and clock differential pairs to make it one bit output and so on for every 7 differential data pairs, and then we should receive our data on each raising…
There are multiple and none of them exactly match my particular cell which is a 12000mAh cell. Below are the available options from chemdata.txt and Chem.ini. Are the parameters from chemdat.txt the only ones that are actually written to the gauge? If…
The security_examples_central project cannot run on CC2640R2 . The projects in ble_examples-ble_examples-2.2 can only run on
CC2650, as picture 1 shows. Picture 2 shows the path where I download ble_examples-ble_examples-2.2 .
Where can I download…
Part Number: CDCE913PERF-EVM Other Parts Discussed in Thread: CDCE913
I have an issue when using the TI programming board. Please advise.
First I uninstall all TI software I have, restarted the computer, and installed ClockPro1v21.exe (unzipped…
OK, progress has been made after the update to the chemistry selection tool. I actually get a report now, which is fantastic! However, it says to use chemistry 4202. I don't have 4204. So, I ran the chemistry updater. Now the chemistry selection table…
Fullscreen
4213.tas5825m.c
Download
/*
* Driver for the TAS5825M Audio Amplifier
*
* Author: Andy Liu <andy-liu@ti.com>
* Author: Dario Murgia <dario.murgia@alumni.uniroma2.eu>
*
* This program is free software; you can redistribute it and…
Hi Alex,
the suffix "G3" is explained here:
4213.TI's Lead Free and Green Program Parts Designations.pdf
There's no difference between the two, if I'm right, only an overlapping from the TI's "changeover to lead-free" era. Both are "green" products…