TI E2E support forums
TI E2E support forums
  • User
  • Site
  • Search
  • User
  • E2E™ design support >
  • Forums
    • Amplifiers
    • API solutions
    • Audio
    • Clock & timing
    • Data converters
    • DLP® products
    • Interface
    • Isolation
    • Logic
    • Microcontrollers
    • Motor drivers
    • Power management
    • Processors
    • RF & microwave
    • Sensors
    • Site support
    • Switches & multiplexers
    • Tools
    • Wireless connectivity
    • Archived forums
    • Archived groups
  • Technical articles
  • TI training
    • Tech days
    • Online training
    • Live events
    • Power Supply Design Seminar
  • Getting started
  • 简体中文
  • More
  • Cancel
Logic

Logic

Logic forum

  • Mentions
  • Tags
  • More
  • Cancel
  • Ask a new question
  • Ask a new question
  • Cancel
Texas Instruments (TI) Logic support forum is an extensive online knowledge base where millions of technical questions and solutions are available 24/7. You can search logic IC content or ask technical support questions on everything from voltage level translation and transceivers to standard logic gates and specialty logic devices. Find the right solution for your circuit design challenges by using our TI E2E™ support forums that are supported by thousands of contributing TI experts.
Frequent questions
  • [FAQ] The thermal information in the datasheet has changed! What does this mean for me?

    Nikki Dengel
    Nikki Dengel
    FAQ: Logic and Voltage Translation > Power and Thermals >> Current FAQ We have been updating the thermal values in our datasheet, so you may have received a notification about datasheet changes to the thermal values or noticed a datasheet revision about…
    • Answered
    • 24 days ago
    • Logic
    • Logic forum
  • [FAQ] Can TXG support IEC-ESD for offboard connections

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ TXG devices (both push-pull and open-drain) cannot support any level of IEC-ESD. However, IEC-ESD can still be achieved by using a protection device like the ESDS30x product…
    • 3 months ago
    • Logic
    • Logic forum
  • [FAQ] How far apart can the two systems be with TXG I2C devices?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG8122-Q1 Since the I2C protocol limits the allowable bus capacitance to 400pF (for Standard and Fast Mode) or 550pF (for Fast Mode+), similar requirements will need to be implemented on the TXG8122-Q1. There are…
    • 3 months ago
    • Logic
    • Logic forum
  • [FAQ] Will TXG QFN packages support wettable flank?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ At the moment TXG QFN packages do not support wettable flanks. However, we are working towards supporting wettable flank packages once products are fully released. The QFN…
    • 3 months ago
    • Logic
    • Logic forum
  • [FAQ] What is the leakage between 2 grounds?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG1041 FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The leakage between two grounds can be found under the Electrical Characteristics section in the datasheet. Using the TXG1041 datasheet…
    • 3 months ago
    • Logic
    • Logic forum
  • [FAQ] Can TXG be used as a simple level translator / buffer?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The TXG product family can be used as a regular level translator (VCCA > VCCB or VCCA < VCCB) or in a buffer configuration (VCCA = VCCB). If a user doesn’t need ground shifting…
    • 3 months ago
    • Logic
    • Logic forum
  • [FAQ] What is the maximum trace length ground-level translators can drive?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The maximum trace length that ground-level translators (as well as logic devices) can drive is 60 mm. This is a safe trace length for most devices to drive across the majority…
    • 5 months ago
    • Logic
    • Logic forum
  • [FAQ] Is DC ground shifting possible when both supplies are connected together?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ To use the ground shift capability, voltage supplies need to be separated and fall within the recommended operating conditions. Let’s use the figure above as an example…
    • 5 months ago
    • Logic
    • Logic forum
  • [FAQ] Can I generate a negative PWM signal from a positive PWM signal?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG8041 FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ A negative signal can be generated from ground-level translators as long as the user’s system has a negative supply rail. To prevent…
    • 5 months ago
    • Logic
    • Logic forum
  • [FAQ] Ground-Level Translators

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > > Current FAQ [FAQ] What are the differences between Ground-Level Translators and Digital Isolators? [FAQ] Can I generate a negative PWM signal from a positive PWM signal? [FAQ] Is DC ground shifting possible…
    • 5 months ago
    • Logic
    • Logic forum
>

View FAQ threads
  • Tags
  • RSS
  • More
  • Cancel
  • Not Answered

    [FAQ] Frequently Asked Questions: TPLD 0 Locked

    1700 views
    0 replies
    Started 9 months ago
    by Malcolm Lyn
  • Answered

    [FAQ] [H] Frequently Asked Questions: Logic and Voltage Translation 0 Locked

    39987 views
    1 reply
    Latest over 4 years ago
    by Michael J Schultis
  • Answered

    TXS0104V-Q1: IBIS model for TXS0104VQRUTRQ1 0

    72 views
    2 replies
    Latest 42 minutes ago
    by Youhei Miyaoka
  • Suggested Answer

    CD74HC14: CD74hc14 part differences 0

    15 views
    1 reply
    Latest 2 hours ago
    by Albert Xu1
  • Suggested Answer

    SN74LVC1G06: PCN issue 0

    12 views
    1 reply
    Latest 2 hours ago
    by Albert Xu1
  • Not Answered

    SN74LVC1G17-Q1: Any issues with Vin > Vcc? 0

    9 views
    0 replies
    Started 3 hours ago
    by Wilson Yip
  • Suggested Answer

    SN74AVC16T245: SN74AVC16T245 0

    16 views
    1 reply
    Latest 4 hours ago
    by Joshua Salinas
  • Suggested Answer

    TMUX1208: Source or Drain negative transient voltage 0

    17 views
    1 reply
    Latest 7 hours ago
    by Nir Gilgur
  • Suggested Answer

    SN74LVC1G3157: SN74LVC1G3157DRYR Package information check 0

    14 views
    1 reply
    Latest 7 hours ago
    by Nir Gilgur
  • Suggested Answer

    SN74LVC07A: Chamfer not available 0

    12 views
    1 reply
    Latest 15 hours ago
    by Clemens Ladisch
  • Suggested Answer

    TXS0108E-Q1: current consumption estimation 0

    83 views
    6 replies
    Latest 15 hours ago
    by Clemens Ladisch
  • Answered

    TXB0108: TXB0108PWR- Output Stuck HIGH (1.8V) despite Correct Input and Isolated Pin 0

    158 views
    7 replies
    Latest 19 hours ago
    by Manish Dhumal
  • Suggested Answer

    TXB0604: TXB0604 suitability for I²S with mixed voltage domains (3.3 V ↔︎ 1.8 V) 0

    35 views
    1 reply
    Latest 3 days ago
    by Jack Guan
  • Suggested Answer

    SN74AXC4T245: High impedance conditions 0

    126 views
    7 replies
    Latest 3 days ago
    by Joshua Salinas
  • Suggested Answer

    SN74AHC1G08: The body mark on PN#016-101417-01-15T MPN#SN74AHC1G08DBVR 0

    41 views
    1 reply
    Latest 3 days ago
    by Nikki Dengel
  • Answered

    SN74LVCC3245A: VCCA=On/VCCB=Off 0

    63 views
    3 replies
    Latest 3 days ago
    by Joshua Salinas
  • Answered

    CD74HCT4067-Q1: CD74HCT4067-Q1 Switching noise 0

    92 views
    7 replies
    Latest 3 days ago
    by Arya Hussein
  • Not Answered

    SN74AHC1G125: Performance discrepancy in SN74AHC1G125DCKR (Marking 1RB vs AMJ) 0

    53 views
    3 replies
    Latest 3 days ago
    by Clemens Ladisch
  • Suggested Answer

    SN74ACT86-Q1: Dual logic gates 0

    150 views
    6 replies
    Latest 3 days ago
    by Albert Xu1
  • Answered

    SN74AHCT240: SN74AHCT240RKSR VQFN-20 package pin configuration not available in datasheet 0

    66 views
    4 replies
    Latest 3 days ago
    by Tso Shiung Lee
>