TI E2E support forums
TI E2E support forums
  • User
  • Site
  • Search
  • User
  • E2E™ design support >
  • Forums
    • Amplifiers
    • API solutions
    • Audio
    • Clock & timing
    • Data converters
    • DLP® products
    • Interface
    • Isolation
    • Logic
    • Microcontrollers
    • Motor drivers
    • Power management
    • Processors
    • RF & microwave
    • Sensors
    • Site support
    • Switches & multiplexers
    • Tools
    • Wireless connectivity
    • Archived forums
    • Archived groups
  • Technical articles
  • TI training
    • Tech days
    • Online training
    • Live events
    • Power Supply Design Seminar
  • Getting started
  • 简体中文
  • More
  • Cancel
Logic

Logic

Logic forum

  • Mentions
  • Tags
  • More
  • Cancel
  • Ask a new question
  • Ask a new question
  • Cancel
Texas Instruments (TI) Logic support forum is an extensive online knowledge base where millions of technical questions and solutions are available 24/7. You can search logic IC content or ask technical support questions on everything from voltage level translation and transceivers to standard logic gates and specialty logic devices. Find the right solution for your circuit design challenges by using our TI E2E™ support forums that are supported by thousands of contributing TI experts.
Frequent questions
  • [FAQ] The thermal information in the datasheet has changed! What does this mean for me?

    Nikki Dengel
    Nikki Dengel
    FAQ: Logic and Voltage Translation > Power and Thermals >> Current FAQ We have been updating the thermal values in our datasheet, so you may have received a notification about datasheet changes to the thermal values or noticed a datasheet revision about…
    • Answered
    • 3 months ago
    • Logic
    • Logic forum
  • [FAQ] Can TXG support IEC-ESD for offboard connections

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ TXG devices (both push-pull and open-drain) cannot support any level of IEC-ESD. However, IEC-ESD can still be achieved by using a protection device like the ESDS30x product…
    • 5 months ago
    • Logic
    • Logic forum
  • [FAQ] How far apart can two systems be when using ground-level translator devices?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG8122-Q1 Open-Drain Architecture For I2C applications, the allowable distance between systems is primarily limited by total bus capacitance. The I2C specification limits bus capacitance to 400pF for Standard and…
    • 5 months ago
    • Logic
    • Logic forum
  • [FAQ] Will TXG QFN packages support wettable flank?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ At the moment TXG QFN packages do not support wettable flanks. However, we are working towards supporting wettable flank packages once products are fully released. The QFN…
    • 5 months ago
    • Logic
    • Logic forum
  • [FAQ] What is the leakage between two grounds?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG1041 FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The leakage between two grounds is specified in the Electrical Characteristics section in the device datasheet. The table below shows…
    • 5 months ago
    • Logic
    • Logic forum
  • [FAQ] Can TXG be used as a simple level translator / buffer?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The TXG product family can be used as a standard level translator (VCCA > VCCB or VCCA < VCCB) or in a buffer configuration when VCCA equals VCCB. If ground shifting is not…
    • 5 months ago
    • Logic
    • Logic forum
  • [FAQ] What is the maximum trace length ground-level translators can drive?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The maximum trace length that ground-level translators (as well as logic devices) can drive is 60 mm. This is a safe trace length for most devices to drive across the majority…
    • 7 months ago
    • Logic
    • Logic forum
  • [FAQ] Is DC ground shifting possible when both supplies are connected together?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ Ground shifting requires the voltage supplies to be separated and to remain within the recommended operating conditions. In the image below, GNDB shifts by -5V due to parasitic…
    • 7 months ago
    • Logic
    • Logic forum
  • [FAQ] Can a negative PWM signal be generated from a positive PWM signal?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG8041 FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ A negative PWM signal can be generated using a ground-level translator if the system includes a negative supply rail. To prevent…
    • 7 months ago
    • Logic
    • Logic forum
  • [FAQ] Ground-Level Translators

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > > Current FAQ [FAQ] What are the differences between Ground-Level Translators and Digital Isolators? [FAQ] Can I generate a negative PWM signal from a positive PWM signal? [FAQ] Is DC ground shifting possible…
    • 7 months ago
    • Logic
    • Logic forum
>

View FAQ threads
  • Tags
  • RSS
  • More
  • Cancel
  • Not Answered

    [FAQ] Frequently Asked Questions: TPLD 0 Locked

    2266 views
    0 replies
    Started 11 months ago
    by Malcolm Lyn
  • Answered

    [FAQ] [H] Frequently Asked Questions: Logic and Voltage Translation 0 Locked

    42509 views
    1 reply
    Latest over 4 years ago
    by Michael J Schultis
  • Suggested Answer

    SN74AXC4T774-Q1: CAXC4T774QRSVRQ1 unused pin 0

    8 views
    1 reply
    Latest 5 minutes ago
    by Joshua Salinas
  • Suggested Answer

    SN74AXC4T774: Regarding the specifications of the internal pull-down resistors 0

    70 views
    3 replies
    Latest 15 minutes ago
    by Joshua Salinas
  • Not Answered

    SN74LS07: Temperature Range 0

    3 views
    0 replies
    Started 32 minutes ago
    by Chris Zebuth
  • Not Answered

    SN74LVC1G37: Question on the component 0

    4 views
    0 replies
    Started 3 hours ago
    by Shahar Yaffe
  • Not Answered

    SN74HC86: Reliability data 0

    2 views
    0 replies
    Started 7 hours ago
    by James Holland
  • Not Answered

    CD4068B: Query on Operating Voltage of CD4068BPWR 0

    5 views
    0 replies
    Started 8 hours ago
    by Shardul Gogate
  • Not Answered

    SN54SC6T07-SEP: Clarification on HIGH-state output curves for SN54SC6T06-SEP / SN54SC6T07-SEP 0

    6 views
    0 replies
    Started 9 hours ago
    by Hisashi Yuda
  • Not Answered

    TPS53679: PIN Configuration 0

    4 views
    0 replies
    Started 9 hours ago
    by Sankar Pulakala
  • Not Answered

    TMUX4051: Power Supply requirements & internal ESD diodes 0

    7 views
    0 replies
    Started 10 hours ago
    by KrnB
  • Not Answered

    CD4013B: CD4013B: Issues Regarding the Clock of CD4013B 0

    8 views
    0 replies
    Started 10 hours ago
    by Enzo Yin
  • Suggested Answer

    TPS3828-Q1: Reset output behavior and internal watchdog transition after WDI timeout 0

    26 views
    2 replies
    Latest 13 hours ago
    by Yuxi Liu(Tony)
  • Not Answered

    SN74LVC1G74: SN74LVC1G74DCUR pin to pin solution with Schnitt-trigger 0

    11 views
    0 replies
    Started 14 hours ago
    by Howard Wei
  • Answered

    TPS2HCS10-Q1: TPS2HCS10-Q1: Tolerance and MIN/MAX values for IOCP (Immediate Shutdown Threshold)? 0

    150 views
    7 replies
    Latest 16 hours ago
    by IKUTA
  • Suggested Answer

    TPLD2001: TPLD as IO expander - understanding limitations 0

    25 views
    1 reply
    Latest 18 hours ago
    by Gerardo Leyva-Hernandez
  • Not Answered

    SN74HC595: SN74HC595 tpd test timing error 0

    6 views
    0 replies
    Started 23 hours ago
    by Thomas Yang55737
  • Suggested Answer

    SN74AVC2T244: Propagation Delay 0

    38 views
    1 reply
    Latest 1 day ago
    by Joshua Salinas
  • Not Answered

    CD74ACT541: Marking callout request for item CD74ACT541M96. <T4909413> 0

    9 views
    0 replies
    Started 1 day ago
    by Nathan Raatz
  • Not Answered

    MSPM0L1306: MSPM0L1306 comparator hysteresis seems to be wrong by n-1 0

    115 views
    3 replies
    Latest 1 day ago
    by Marcus Alexander Tjomsaas
>