TI E2E support forums
TI E2E support forums
  • User
  • Site
  • Search
  • User
  • E2E™ design support >
  • Forums
    • Amplifiers
    • API solutions
    • Audio
    • Clock & timing
    • Data converters
    • DLP® products
    • Interface
    • Isolation
    • Logic
    • Microcontrollers
    • Motor drivers
    • Power management
    • Processors
    • RF & microwave
    • Sensors
    • Site support
    • Switches & multiplexers
    • Tools
    • Wireless connectivity
    • Archived forums
    • Archived groups
  • Technical articles
  • TI training
    • Tech days
    • Online training
    • Live events
    • Power Supply Design Seminar
  • Getting started
  • 简体中文
  • More
  • Cancel
Data converters

Data converters

Data converters forum

  • Mentions
  • Tags
  • More
  • Cancel
  • Ask a new question
  • Ask a new question
  • Cancel
Texas Instruments (TI) Data converters support forum is an extensive online knowledge base where millions of technical questions and solutions are available 24/7. You can search data converter IC content or ask technical support questions on everything from analog to digital converters (ADCs) and digital to analog converters (DACs) to high speed ADCs and special function data converters. Find the right solution for your circuit design challenges by using our TI E2E™ support forums that are supported by thousands of contributing TI experts.
Frequent questions
  • [FAQ] DAC8775: How is the SDO mode controlled in SPI?

    Joseph Wu
    Joseph Wu
    Other Parts Discussed in Thread: DAC8775 , DAC8771 How is the SDO mode controlled for SPI for the DAC8775 and DAC8771?
    • Answered
    • 8 months ago
    • Data converters
    • Data converters forum
  • [FAQ] Which TI devices support the HART protocol?

    Joseph Wu
    Joseph Wu
    Part Number: AFE881H1 Other Parts Discussed in Thread: DAC161S997 , DAC161P997 , DAC8750 , DAC7750 , DAC8760 , DAC7760 , DAC8771 , DAC8775 , DAC8740H , DAC8741H , DAC8742H , , AFE781H1 , AFE882H1 , AFE782H1 Tool/software: Which TI devices support…
    • Answered
    • 9 months ago
    • Data converters
    • Data converters forum
  • [FAQ] LMP90100: Reading data from the LMP90100 registers

    Angel Rodriguez de San Miguel Bermudez
    Angel Rodriguez de San Miguel Bermudez
    Part Number: LMP90100 Other Parts Discussed in Thread: LMP90099 , LMP90098 , LMP90097 , LMP90080 , LMP90079 , LMP90078 , LMP90077 , LMP90080-Q1 Tool/software: Hi, What is the protocol to read register data on my LMP90100?
    • Answered
    • over 1 year ago
    • Data converters
    • Data converters forum
  • [FAQ] LMP90100: CRC value reading as zeroes

    Angel Rodriguez de San Miguel Bermudez
    Angel Rodriguez de San Miguel Bermudez
    Part Number: LMP90100 Other Parts Discussed in Thread: LMP90099 , LMP90098 , LMP90097 , LMP90080 , LMP90079 , LMP90078 , LMP90077 , LMP90080-Q1 Tool/software: Hi, I'm enabling the CRC function in my LMP90100, but I'm only reading zeroes when I read…
    • Answered
    • over 1 year ago
    • Data converters
    • Data converters forum
  • [FAQ] LMP90080: CRC function in LMP90080

    Angel Rodriguez de San Miguel Bermudez
    Angel Rodriguez de San Miguel Bermudez
    Part Number: LMP90080 Other Parts Discussed in Thread: LMP90100 , LMP90099 , LMP90098 , LMP90097 , LMP90079 , LMP90078 , LMP90077 , Tool/software: Hi, I’m trying to use CRC to ensure integrity of data on my LMP90080, but my externally calculated value…
    • Answered
    • over 1 year ago
    • Data converters
    • Data converters forum
  • [FAQ] ADS1298R: How are the lead-off comparator thresholds set?

    Ryan Andrews
    Ryan Andrews
    Tool/software: In the ADS129x family, a 4-bit DAC is used to set the lead-off detection threshold for the positive and negative channels inputs. The DAC settings are configured writing to COMP_TH[2:0] in the LOFF control register. The threshold voltages…
    • over 1 year ago
    • Data converters
    • Data converters forum
  • [FAQ] ADS1263EVM-PDK: Where are the software plugin and user's guide for the previous revision (MMB0-based) of the ADS1263EVM?

    Bryan Lizon86
    Bryan Lizon86
    Part Number: ADS1263EVM-PDK Hi, I received an ADS1263EVM-PDK but it is not the version shown on TI.com. It comes with an MMB0 controller board instead of the PHI controller, and looks like the image below Can you please help me find the software…
    • Answered
    • over 2 years ago
    • Data converters
    • Data converters forum
  • [FAQ] ADS127L21: How do I design custom IIR and FIR filters?

    Keith Nicholas
    Keith Nicholas
    Part Number: ADS127L21 The ADS127L21 ADC includes programmable infinite and finite impulse response (IIR and FIR) digital filters that allow custom filter profiles, such as frequency notch filters. How do I design these custom filters?
    • Answered
    • over 2 years ago
    • Data converters
    • Data converters forum
  • [FAQ] ADS7066: Integrated features to aid Functional Safety Analysis

    Josh Brown
    Josh Brown
    Part Number: ADS7066 Hello, see the integrated features of the ADS7066 that can aid in the functional safety analysis of a system: . ADS7066 Consolidated.pptx
    • over 2 years ago
    • Data converters
    • Data converters forum
  • [FAQ] ADS131B26-Q1: Device resets when disabling the AVDD or IOVDD overvoltage diagnostic

    Joachim Wuerker
    Joachim Wuerker
    Part Number: ADS131B26-Q1 Hello, I am using the ADS131B26-Q1 in a functionally safe battery management system (BMS). I am leveraging the various integrated device diagnostics to meet my latent fault metric (LFM). I noticed that the device resets under…
    • Answered
    • over 2 years ago
    • Data converters
    • Data converters forum
>

View FAQ threads
  • Tags
  • RSS
  • More
  • Cancel
  • Not Answered

    ADS1248EVM-PDK: ads1248evm-pdk connection failed 0

    9 views
    0 replies
    Started 1 hour ago
    by Jianzhou Li
  • Suggested Answer

    ADS7280: Single manual conversion start for two channel reads 0

    21 views
    1 reply
    Latest 4 hours ago
    by Samiha Sharif
  • Suggested Answer

    ADS7952: ADS7952 REFP and ANALOG INPUT Rise Time Sequence 0

    39 views
    2 replies
    Latest 5 hours ago
    by Hiroyuki Itoh
  • Not Answered

    ADC3544: In attempt to output parallel complex DDR data 0

    52 views
    5 replies
    Latest 5 hours ago
    by Rob Reeder
  • Suggested Answer

    AFE4404: Hardware-Power-Down 0

    91 views
    6 replies
    Latest 5 hours ago
    by Pawel Potok
  • Suggested Answer

    ADC128S102QML-SP: Safety of Digital Inputs of ADC 0

    11 views
    1 reply
    Latest 6 hours ago
    by Joel Meraz
  • Answered

    ADS1298R: RLD LOFF detection 0

    26 views
    2 replies
    Latest 6 hours ago
    by Alex Lasenby
  • Answered

    DAC53401: Adjusting REF_EN and DAC_span on the fly? 0

    26 views
    1 reply
    Latest 8 hours ago
    by Erin Bowrie
  • Not Answered

    ADS8363: Regarding the ADC to be used with the AMC3330 output 0

    21 views
    1 reply
    Latest 9 hours ago
    by Josh Brown
  • Not Answered

    ADS8681: Synchronization of 1MSPS SPI ADC Without FIFO Using MCU SPI Master + DMA 0

    24 views
    1 reply
    Latest 10 hours ago
    by Yolanda Gonzalez
  • Answered

    ADS122S14: Input impedance at startup 0

    66 views
    4 replies
    Latest 10 hours ago
    by Ben van den Bergh
  • Not Answered

    ADC3683EVM: ADC36xxEVM GUI Error when following Instructions 0

    32 views
    6 replies
    Latest 11 hours ago
    by Luke Allen
  • Not Answered

    ADS1100: The I2C register issue for ADS1100 0

    14 views
    0 replies
    Started 13 hours ago
    by Zhang Liang
  • Not Answered

    ADC12DL1500: Sub-Nyquist Sampling 0

    14 views
    1 reply
    Latest 13 hours ago
    by Rob Reeder
  • Suggested Answer

    ADC34RF72: Abnormal VCM behavior when driving multiple LMH5401 channels from ADC34RF72 0

    139 views
    9 replies
    Latest 14 hours ago
    by Rob Reeder
  • Suggested Answer

    ADC32RF55EVM: 485780_ADC32RF55EVM_Received_Damaged_Board(Component chip off) 0

    34 views
    4 replies
    Latest 14 hours ago
    by Rob Reeder
  • Not Answered

    ADS7066: Daisy-Chain Support and Control Timing Clarification 0

    11 views
    0 replies
    Started 17 hours ago
    by Conor
  • Suggested Answer

    ADC128S102EVM: Continuous Export 0

    76 views
    3 replies
    Latest 21 hours ago
    by Joel Meraz
  • Answered

    ADC32RF55: Overrange settings 0

    62 views
    3 replies
    Latest 1 day ago
    by Kei Kuwahara
  • Not Answered

    ADS54J40: ENOB at lower input signal frequency 0

    20 views
    1 reply
    Latest 1 day ago
    by Rob Reeder
>