TI E2E support forums
TI E2E support forums
  • User
  • Site
  • Search
  • User
  • E2E™ design support >
  • Forums
    • Amplifiers
    • API solutions
    • Audio
    • Clock & timing
    • Data converters
    • DLP® products
    • Interface
    • Isolation
    • Logic
    • Microcontrollers
    • Motor drivers
    • Power management
    • Processors
    • RF & microwave
    • Sensors
    • Site support
    • Switches & multiplexers
    • Tools
    • Wireless connectivity
    • Archived forums
    • Archived groups
  • Technical articles
  • TI training
    • Tech days
    • Online training
    • Live events
    • Power Supply Design Seminar
  • Getting started
  • 简体中文
  • More
  • Cancel
Logic

Logic

Logic forum

  • Mentions
  • Tags
  • More
  • Cancel
  • Ask a new question
  • Ask a new question
  • Cancel
Texas Instruments (TI) Logic support forum is an extensive online knowledge base where millions of technical questions and solutions are available 24/7. You can search logic IC content or ask technical support questions on everything from voltage level translation and transceivers to standard logic gates and specialty logic devices. Find the right solution for your circuit design challenges by using our TI E2E™ support forums that are supported by thousands of contributing TI experts.
Frequent questions
  • [FAQ] The thermal information in the datasheet has changed! What does this mean for me?

    Nikki Dengel
    Nikki Dengel
    FAQ: Logic and Voltage Translation > Power and Thermals >> Current FAQ We have been updating the thermal values in our datasheet, so you may have received a notification about datasheet changes to the thermal values or noticed a datasheet revision about…
    • Answered
    • 5 months ago
    • Logic
    • Logic forum
  • [FAQ] Can TXG support IEC-ESD for offboard connections

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ TXG devices (both push-pull and open-drain) cannot support any level of IEC-ESD. However, IEC-ESD can still be achieved by using a protection device like the ESDS30x product…
    • 8 months ago
    • Logic
    • Logic forum
  • [FAQ] How far apart can two systems be when using ground-level translator devices?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG8122-Q1 Open-Drain Architecture For I2C applications, the allowable distance between systems is primarily limited by total bus capacitance. The I2C specification limits bus capacitance to 400pF for Standard and…
    • 8 months ago
    • Logic
    • Logic forum
  • [FAQ] Will TXG QFN packages support wettable flank?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ At the moment TXG QFN packages do not support wettable flanks. However, we are working towards supporting wettable flank packages once products are fully released. The QFN…
    • 8 months ago
    • Logic
    • Logic forum
  • [FAQ] What is the leakage between two grounds?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG1041 FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The leakage between two grounds is specified in the Electrical Characteristics section in the device datasheet. The table below shows…
    • 8 months ago
    • Logic
    • Logic forum
  • [FAQ] Can TXG be used as a simple level translator / buffer?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The TXG product family can be used as a standard level translator (VCCA > VCCB or VCCA < VCCB) or in a buffer configuration when VCCA equals VCCB. If ground shifting is not…
    • 8 months ago
    • Logic
    • Logic forum
  • [FAQ] What is the maximum trace length ground-level translators can drive?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ The maximum trace length that ground-level translators (as well as logic devices) can drive is 60 mm. This is a safe trace length for most devices to drive across the majority…
    • 10 months ago
    • Logic
    • Logic forum
  • [FAQ] Is DC ground shifting possible when both supplies are connected together?

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ Ground shifting requires the voltage supplies to be separated and to remain within the recommended operating conditions. In the image below, GNDB shifts by -5V due to parasitic…
    • 10 months ago
    • Logic
    • Logic forum
  • [FAQ] Can a negative PWM signal be generated from a positive PWM signal?

    Joshua Salinas
    Joshua Salinas
    Other Parts Discussed in Thread: TXG8041 FAQ: Logic and Voltage Translation > Ground-Level Translators >> Current FAQ A negative PWM signal can be generated using a ground-level translator if the system includes a negative supply rail. To prevent…
    • 10 months ago
    • Logic
    • Logic forum
  • [FAQ] Ground-Level Translators

    Joshua Salinas
    Joshua Salinas
    FAQ: Logic and Voltage Translation > > Current FAQ [FAQ] What are the differences between Ground-Level Translators and Digital Isolators? [FAQ] Can I generate a negative PWM signal from a positive PWM signal? [FAQ] Is DC ground shifting possible…
    • 10 months ago
    • Logic
    • Logic forum
>

View FAQ threads
  • Tags
  • RSS
  • More
  • Cancel
  • Not Answered

    [FAQ] Frequently Asked Questions: TPLD 0 Locked

    2749 views
    0 replies
    Started over 1 year ago
    by Malcolm Lyn
  • Answered

    [FAQ] [H] Frequently Asked Questions: Logic and Voltage Translation 0 Locked

    45057 views
    1 reply
    Latest over 4 years ago
    by Michael J Schultis
  • Suggested Answer

    CD4013B: REMINDER - HEMERIA [140-052026] - SU2102-0013 - TEXAS INSTRUMENTS FRANCE 0

    30 views
    2 replies
    Latest 12 minutes ago
    by Clemens Ladisch
  • Suggested Answer

    SN74AVC2T244: Voltage Level Translator Outputs External OR Connections 0

    62 views
    6 replies
    Latest 36 minutes ago
    by Clemens Ladisch
  • Not Answered

    CD4002B: URGENT - REMINDER - HEMERIA [140-052026] - SU2102-0013 - TEXAS INSTRUMENTS FRANCE 0

    2 views
    0 replies
    Started 46 minutes ago
    by Elise RUPAIRE
  • Suggested Answer

    TPLD1202: InterConnect Studio fail to load the example code 0

    41 views
    2 replies
    Latest 2 hours ago
    by PYTsai
  • Not Answered

    TPS3823: Watchdog Timeout Period (t_tout) Shorter Than Datasheet Minimum Specification (Single Unit Issue) 0

    10 views
    0 replies
    Started 3 hours ago
    by Yuxi Liu(Tony)
  • Not Answered

    TPS3820: TPS3820 WDI Not Recognized Despite Compliant Signal, Batch Constant System Reset 0

    35 views
    1 reply
    Latest 12 hours ago
    by Sila Atalar
  • Suggested Answer

    SN74LV14A: Data request from Flex 0

    43 views
    2 replies
    Latest 15 hours ago
    by Manikandan M
  • Suggested Answer

    SN74AVC4T774: output jitter 0

    18 views
    1 reply
    Latest 16 hours ago
    by Joshua Salinas
  • Answered

    TXS0108E-Q1: Inquiry regarding the operational characteristics of the TXS0108E 0

    33 views
    2 replies
    Latest 1 day ago
    by DAEPYO HWANG
  • Answered

    TXB0106-Q1: Dealing with un-used pins on the TXB0106-Q1 level shifter 0

    19 views
    1 reply
    Latest 1 day ago
    by Jack Guan
  • Suggested Answer

    SN74LVC2G14-Q1: Temperature rating 0

    23 views
    1 reply
    Latest 1 day ago
    by Malcolm Lyn
  • Suggested Answer

    SN74LVC1G123: can you help review the SN74LVC1G123 logic design is expected or not 0

    33 views
    1 reply
    Latest 1 day ago
    by Malcolm Lyn
  • Answered

    SN74LVC2G74: G4 suffix impact on SMT 0

    34 views
    1 reply
    Latest 1 day ago
    by Malcolm Lyn
  • Answered

    CD4007UB: TI* CD4007UBMT issue and question 0

    16 views
    1 reply
    Latest 1 day ago
    by Clemens Ladisch
  • Suggested Answer

    SN74AHCT125: load capacitance = 100pF 0

    114 views
    5 replies
    Latest 1 day ago
    by Clemens Ladisch
  • Answered

    SN74LVC2G04: SN74LVC2G04YZPR About the pin assignment 0

    17 views
    1 reply
    Latest 1 day ago
    by Clemens Ladisch
  • Suggested Answer

    SN74LVC2T45: The FMEDA file for SN74LVC2T45 0

    26 views
    1 reply
    Latest 1 day ago
    by Joshua Salinas
  • Suggested Answer

    TXS0102: DC Analysis data for digital switching level. 0

    33 views
    1 reply
    Latest 2 days ago
    by Clemens Ladisch
>